K2 Dome V System (Archive)

K2 Dome V System

Time saving due to simultaneous assembly, reduced screw connections. Available elevated on one/two sides.
  • Our know-how of the last few years, many optimisations and improvements have gone into these systems.
  • Clearly ballast- and component-optimized system due to better friction coefficient of the flexible support pad
  • Simultaneous assembly of modules and mounting system as well as reduced screw connections ensure faster installation
  • Lower logistics costs due to lower transport volume

K2 Dome V System

K2 Dome V System

Technical data

D-Dome V 10°
S-Dome V 10° / 15°
Scope of application Flat roofs ≤ 5° with single ply membrane or bituminous roof covering, also on concrete, gravelled or green roofs Flat roofs ≤ 5° with single ply membrane or bituminous roof covering, also on concrete, gravelled or green roofs
Fastening type/roof fixture
Ballasted; no roof penetration for inclination ≤ 3°
Ballasted; no roof penetration for inclination ≤ 3°
Requirements
  • Permissible module dimensions (L×W×H): 1386-2100 × 985-1053 × 30-50mm
  • Minimum system size: 2 supports (4 modules)
  • Module approved for corner clamping (see approved modules…)
  • Permissible module dimensions (L×W×H): 1550-1760 / 1880-2100 × 950-1053 × 30-50mm
  • Minimum system size: 2 modules
  • Module approved for corner clamping (see approved modules…)
Technical specifications
  • Thermal separation after a maximum of 15.5m
  • Minimum distance to the edge of the roof 600mm
  • Thermal separation after a maximum of 15.5m
  • Minimum distance to the edge of the roof 600mm
Inclination angle 10° 10° / 15°
Material
  • Mounting rails, Peak, Basic, SD, Windbreaker and MiniClamps: Aluminium EN AW-6063 T66 and AW-6082 T6
  • Mat V protective mat: EPDM
  • Small parts: stainless steel (1.4301) A2-70
  • Mounting rails, Peak, Basic, SD and MiniClamps: Aluminium EN AW-6063 T66 and AW-6082 T6
  • Windbreaker: Magnelis
  • Mat V protective mat: EPDM
  • Small parts: stainless steel (1.4301) A2-70

K2 Dome V System

Downloads

Product data sheet

Brochure - Flat roof systems

Assembly instructions - D-Dome V

Assembly instructions - S-Dome V

Checklist - Flat roof

General Assembly and Maintenance Instructions

Tender speci­fi­ca­tion - D-Dome V 10°

DE EN

Tender speci­fi­ca­tion - S-Dome V 10°

DE EN

Tender speci­fi­ca­tion - S-Dome V 15°

DE EN

Expert's report wind loads - D-Dome V 10°

DE EN

Expert's report wind loads - S-Dome V 10°

DE EN

Expert's report wind loads - S-Dome V 15°

DE EN

Certificate Structural Analyses - D-Dome V 10°

DE EN

Certificate Structural Analyses - S-Dome V 15°

DE EN

Module approval flat roof systems: Dome V

Recommendations lightning protection and equipotential bonding

DE EN

Protocol Static Friction (Coefficient of Friction)

TerraGrif - Potential equalisation

DE EN FR

K2 Dome V System